HP Smart Storage Arrays monitoring with Netdata
Monitors controller, cache module, logical and physical drive state and temperature using ssacli tool.
Executed commands:
sudo -n ssacli ctrl all show config detail
Requirements:#
This module uses ssacli, which can only be executed by root. It uses
sudo and assumes that it is configured such that the netdata user can execute ssacli as root without a password.
- Add to your
/etc/sudoersfile:
which ssacli shows the full path to the binary.
- Reset Netdata's systemd unit CapabilityBoundingSet (Linux distributions with systemd)
The default CapabilityBoundingSet doesn't allow using sudo, and is quite strict in general. Resetting is not optimal, but a next-best solution given the inability to execute ssacli using sudo.
As the root user, do the following:
Charts#
- Controller status
- Controller temperature
- Logical drive status
- Physical drive status
- Physical drive temperature
Enable the collector#
The hpssa collector is disabled by default. To enable it, use edit-config from the
Netdata config directory, which is typically at /etc/netdata, to edit the python.d.conf
file.
Change the value of the hpssa setting to yes. Save the file and restart the Netdata Agent with sudo systemctl
restart netdata, or the appropriate method for your system.
Configuration#
Edit the python.d/hpssa.conf configuration file using edit-config from the
Netdata config directory, which is typically at /etc/netdata.
If ssacli cannot be found in the PATH, configure it in hpssa.conf.
Save the file and restart the Netdata Agent with sudo systemctl restart netdata, or the appropriate
method for your system.